3.0
STARTING UP
3.1
UNPACKING THE SET
The set is delivered in cardboard packaging on a wooden base.
WARNING: THE PLASTIC HANDLES ARE NOT INTENDED
FOR SUSPENDING THE SET. DEVICE STABILITY IS ONLY
GUARANTEED ONLY FOR A MAXIMUM INCLINE OF 10°.
3.2
ELECTRICAL CONNECTION
The equipment is an automatic multi voltage set. It is delivered
ready to be connected to a 230V or 400V supply.
- Connect the primary cable (4x2.5 mm2 conductors) to a 3-
phase + ground socket. (If you need to use an extension ca-
ble refer to chapter 4 «INSTRUCTIONS FOR USE», para-
graph 4.3 «Recommendations for use»).
- Check that the fuse sizes correspond with the max. current
consumptions given on page 2.
- Connect your work site or workpiece to be cut to your
ground circuit as explained in the "SAFETY INSTRUC-
TIONS".
CAUTION: THIS EQUIPMENT DOES NOT COMPLY WITH IEC
61000-3-12. BEFORE CONNECTING TO ANY PUBLIC LOW-
VOLTAGE NETWORK THE INSTALLER OR USER OF THE
EQUIPMENT MUST CHECK TO ENSURE THE EQUIPMENT
MAY BE CONNECTED TO SUCH SYSTEM; SUCH CHECKS
MAY NECESSITATE CONSULTING WITH THE DISTRIBUTION
NETWORK OPERATOR.
CAUTION: THIS CLASS A EQUIPMENT IS NOT INTENDED
FOR USE IN RESIDENTIAL AREAS WHERE ELECTRICITY IS
SUPPLIED BY THE PUBLIC LOW-VOLTAGE NETWORK. EN-
SURING ELECTROMAGNETIC COMPATIBILITY AT SUCH
SITES MAY BE IMPOSSIBLE DUE TO CONDUCTED AND RA-
DIATED ELECTROMAGNETIC INTERFERENCE (EMI).
3.3
COMPRESSED AIR CONNECTION
Connect the air inlet pipe to your compressed air circuit with a
quick-release connection.
Minimum pressure
Maximum pressure
Working pressure
Air flow
IMPORTANT: ANY MODIFICATION TO THE AIR INLET CON-
NECTIONS OR THE PRESSURE VALVE/PIPE COMBINATION
MAY HAVE A NEGATIVE EFFECT ON CUTTING PERFOR-
MANCE!
WARNING: IT IS IMPORTANT TO DRAIN THE COMPRESSED
AIR FILTER TANK REGULARLY.
3.4
TORCH EQUIPMENT
Verify that the interchangeable torch parts match the work being
performed (cut / gouging) -> (see IEE CITORCH P40C or PT100).
4.0
INSTRUCTIONS FOR USE
4.1
STARTING UP
After making the connections, fix the ground on the work piece to
be cut making sure that there is a good electrical contact, espe-
cially on painted or oxidised parts.
- Switch the 0/1 on/off switch to position 1.
STARTING UP
4.2 bars
6 bars
5 bars
180 litres / minute
- Fit the wearing parts on the torch.
1
2
3
- Adjust the current with the encoder.
- Consult the current/pressure and warning
messages on the display
4.2
DESCRIPTION OF FUNCTION
There are two possibilities in this mode.
First possibilty: CHOICE OF THE «CONTACT» CUTTING
MODE
This cutting mode is the best for quality and accessibility. It is rec-
ommended when cutting material up to 8 mm in thickness.
Step 1: Fit the torch with its wearing parts
1
1. Thin electrode
2
2. Nozzle
3. Contact cutting skirt
3
Step 3: Press the reset key.
4 EN
- Using the «OK» button select: Pres-
sure adjustment indicator light
- Adjust the air pressure P to 5 bars us-
ing the Regulator-filter handwheel at
the back of the set and checking the
pressure on the gauge.
- Use the «OK» push button to select
one of the 3 operating modes:
1. Cutting mode
2. Mesh mode
3. Gouging mode
Step 2: Adjust the current with the
encoder
EN