Additional charge
-
Compensation
-
charge
To disconnect the charger from the battery, proceed as follows:
Unplugging the
-
charger
-
Symbols used
Warning notices
affixed to the
charger
"Final charge/Additional charge" indicator (3) flashes.
Battery is being completely charged. A cell equalisation charge is now initiated.
"Compensation Charge" indicator (4) is lit up.
After completing final charge, the battery charger automati-cally switches over to
compensation charge. This charge compensates for the battery's self-discharge.
The battery is kept always ready for use, and may stay connected to the charger for
any length of time.
Push the Stop button (6) on the battery charger
Unplug the charging plug
NOTE! Please note that for operational reasons, the fan may run at varying
speeds. The battery charger is fully functional, however.
Follow operating instructions
Connect battery poles correctly:
(+) red (-) black
Detonating gas is generated in the battery during charging.
Risk of explosion!
The charger heats up depending on operating conditions.
Before disconnecting the charger lead from the battery,
interrupt charging
Chargers may only be opened by a qualified electrician
Avoid flames and sparks during charging.
Ensure adequate ventilation during charging.
Battery acid is corrosive.
For indoor use only.
Do not expose to rain.