DISINFECTION
If the equipment has remained unused for a long period
in
temperate
surroundings,
necessary for the softeners without BIO. This operation
must be carried out by a qualified technician.
REGULATORY DISPOSITIONS :
The EC labelling of this BEWAMAT attests its conformity to
the requirements of :
directive
2004/108/EC
-
electromagnetic compatibility
directive
2006/95/EC
-
equipment destined to be used within certain
limits of voltage.
This BEWAMAT is subject to directive 97/23/EEC of
29/05/97 relating to equipments under pressure. It fulfils
the requirements of article 3, point 3 (design and
manufacture according to the rules of the art in use) but
does not come into categories I to IV and hence is not
concerned by EC labelling relating to equipment under
pressure.
This device is not intended for use by persons (including
children) whose physical, sensory or mental is reduced,
or persons lacking experience or knowledge, unless they
have received through a person responsible for their
safety, supervision or instruction concerning prior use of
the device.
Ensure that children do not play with the device.
Technical data:
Supply voltage
Power consumption
Maximum pressure
Minimum pressure
Minimum regeneration output
Water temperature
Ambient temperature
ind.04 du 26/11/2009
disinfection
may
be
relating
to
the
relating
to
electrical
: 230 volts 50/60 Hz
: 6 VA in operation
: 25 VA in regeneration
: 6 bars static
: 1.5 bar dynamic
: 0,5 m³/h
: min. 1°C
: max. 30°C
: min. 5°C
: max. 40°C
GB-
Characteristics
Volume of resin
in litres
Exchange capacity
3
in °f.m
standard
Exchange capacity
3
in °dH.m
standard
Weight of salt per
regeneration in kg
Utilisation output
3
in m
/h minimum
Nominal output
3
in m
/h
10
Instruction BEWAMAT
+
+
25
50
75
10
16
20
45
80
100
25
45
60
1.2
2.0
2.5
0.35
0.35
0.35
1.0
2.0
2.5
P0010923
+