OPERATION (
'
con
CODE READY™ TECHNOLOGY ACTIVATION
The Code Ready Technology option allows to change the blower output from the 600 CFM factory setting to a
maximum of 400 CFM or 300 CFM . Activating the CRT option will reduce the airflow, so that the powerpack insert
will perform within the allowable limit of Make-Up Air (MUA) codes (to meet some building code requirements) . Do not
change the blower CFM setting unless this change is required by code . This change will alter the performance of the
product .
iMPortant notes: 1. This change CANNOT be reverted.
2. CRT can only be set within the first 5 minutes of applying power to the unit.
3. A power outage will not deactivate the CRT.
4. Fan and lights must be OFF.
CRT PROCEDURE
1 . Switch power ON using the main power switch (located behind the filters) and press simultaneously on Fan (A) and
Lights (B) keys for 5 seconds; Fan (A) and Lights (B) key backlights will now flash to indicate you entered the CRT
menu .
400 cFM
MaxiMuM airFlow
2 . To select the 400 CFM maximum airflow, press on the Fan (A) key for 5 seconds, then release; the Fan key backlight
will now flash to indicate 400 CFM has been selected (the Light (B) key backlight will be shut) .
3 . A second 5-second press on the Fan (A) key and release confirms the selection; the Fan key backlight quickly flashes
twice, and the buzzer sounds a double beep . The user interface returns to normal operation .
4 . Locate the CRT sticker near the HVI Certification label inside the powerpack insert, behind the filters .
Check the proper box (400 CFM) .
300 cFM
MaxiMuM airFlow
2 . To select the 300 CFM maximum airflow, press on the Lights (B) key for 5 seconds, then release; the Lights key
backlight will now flash to indicate 300 CFM has been selected (the Fan (A) key backlight will be shut) .
3 . A second 5-second press on the Lights (B) key and release confirms the selection; the Lights key backlight quickly
flashes twice, and the buzzer sounds a double beep . The user interface returns to normal operation .
4 . Locate the CRT sticker near the HVI Certification label inside the powerpack insert, behind the filters .
Check the proper box (300 CFM) .
)