PREPARE THE UNIT
a
ll installations
1 . If present, remove all protective polyfilm from the unit and/
or parts .
2 . Remove the grease filters by pushing down on latch tab
and tilting the filters downward (FIG . 14) . Set aside the
filters .
3 . Disassemble the electrical compartment cover (grey part
in FIG . 15) from inside the unit by removing its retaining
screw . Remove the parts bag behind the cover . Set aside
the parts bag and the cover along with its screw .
4 . Punch out one of the two knock-out holes . Install an
appropriate 7/8" diameter strain relief (not included, grey
part in FIG . 16) .
NOTE: The HCK44 cord connection kit (optional) can
be used instead of the house power cable . Refer to the
instruction packed with the HCK44 cord connection kit .
H
orizontal exHaust installation only
5 . Remove and discard the screw circled in FIG . 17 .
NOTE: This screw might be present or not .
6 . Unplug the blower cable from its connector on faceplate .
Disassemble the faceplate from the unit by removing its
4 retaining screws (two per side, circled in FIG . 18) . Set
aside the faceplate along with its screws .
10
HD1437
HD1438
HD1358
HD1443
HD1444
FIG. 14
SCREW
FIG. 15
FIG. 16
FIG. 17