WIRING
!
WARNING
Risk of electric shock . Electrical wiring must be
done by qualified personnel in accordance with all
applicable codes and standards . Before connecting
wires, switch power off at service panel and lock
service disconnecting means to prevent power from
being switched on accidentally .
1 . Using appropriate wire nuts (not included), connect house
power cable to unit wiring: BLACK to BLACK, WHITE to
WHITE and GREEN or bare wire to GREEN ground screw
(FIG . 30) .
2 . Reinstall the electrical cover in the unit; ensuring the bottom
tabs are inserted in their embossed location . Secure in
place using its retaining screw (FIG . 31) .
CAUTION
Take care not to pinch wires while reinstalling wiring
cover .
INSTALL THE FILTERS
Ducted Installation
Reinstall the grease filters .
Non-Ducted Installation
Attach the non-ducted filters (included with the HARKBN30
non-duct kit) to the back of the grease filters using clips
(provided with non-ducted filter) . To order new non-ducted
filters, use service part number S99010464-130 .
WHITE WIRE
GREEN
GROUND
SCREW
HE0432
HD1379
BLACK
WIRE
HOUSE
POWER
CABLE
FIG. 30
TABS
FIG. 31