Repeat the above procedures for
the other cooking zones for which
you wish to set the timer.
Timer cannot be adjusted unless
the cooking zone and the temper-
ature value for the cooking zone
are selected.
When the cooking zone for which a
timer was set is selected, you can
see the remaining time by touching
the
key again.
Deactivating the timer
Once the set time is over, the hob will auto-
matically turn off and give an audible
warning. Press any key to silence the audio
warning.
Turning off the timers earlier
ü If you turn off the timer earlier, the hob
will carry on operating at the set tem-
perature until it is turned off.
1. Select the cooking zone you want to
turn off.
2. Touch
key to turn the timer on.
3. Until "00" appears on the timer screen,
touch
to set the value to "00".
ð Dot shaped light on the relevant cook-
ing zone display itself turns off com-
pletely after having flashed for a cer-
tain period of time and the timer is
cancelled.
Temperature level
0
1
2
3
4
5
6
7
8
Using induction cooking zones safely and
efficiently
Operating principles: Induction hob heats
directly the cooking vessel as a feature of
its operating principles. Therefore, it has
various advantages when compared to
other hob types. It operates more effi-
ciently and the hob surface does not heat
up. Induction hob is equipped with super-
ior safety systems that will provide you
maximum usage safety.
Your hob can be equipped with in-
duction cooking zones with a dia-
meter of 145, 180, 210-280 mm
depending on the model. With in-
duction feature, each cooking zone
detects each vessel placed on
them. Energy builds up only where
the vessel contacts with the cook-
ing zone and thus, minimum en-
ergy consumption is achieved.
Automatic turning off system
The hob control has an automatic turn off
system. If one or more hob zone(s) are left
on, the hob zone turns off automatically
after a while (See Table-1). In case of a
timer assigned to the hob, the timer screen
is turned off then, too. The time limit for
automatic turn off depends on the selected
temperature level. Maximum operating
period is applied for this temperature level.
The hob zone may be operated by the user
again after it is turned off automatically as
described above.
Automatic turning off periods - hours
0
6
6
5
5
4
1,5
1,5
1,5