Futurelight CC-200 Color changer Mode D'emploi page 34

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

[Down] keys to select „On" if you wish to switch on the lamp automatically after switching on the fixture or
„Off" if you wish the lamp off after switching on the fixture and press [Enter] to confirm or [Mode] to cancel
and return to the menu.
- DMX values
Readout DMX values of each channel received by the fixture. Use the [Up] and [Down] keys to select
desired channel and press [Enter] to read its value coming to the fixture or [Mode] to cancel and return to
the menu.
- Automatic blackout of Display
This function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any
key on the control board. Use the [Up] and [Down] keys to select "On" if you wish to keep the display on or
"Off" if you wish to turn off automatically 2 minutes after last pressing any key on the Control Board and
press [Enter] to confirm or [Mode] to cancel and return to the menu.
- Display intensity
With this function, you can adjust the display-intensity from 20 to 100. Use the [Up] and [Down] keys to
select the level of the display-intensity and press [Enter] to confirm or [Mode] to cancel and return to the
menu.
- Lamp off via DMX
This function allows you to switch off the lamp by DMX. Use the [Up] and [Down] keys to select "On" if you
want to switch off the lamp by DMX or "Off" if you don't want to switch off the lamp by DMX and press
[Enter] to confirm or [Mode] to cancel and return to the menu.
- Temperature
Inside temperature readouts of the fixture in Celsius. Inside temperatures below 80° C are not critical. 80° C
and more lead to the lamp being switched off. Please note that the outside temperature should not exceed
55° C.
- Fan speed operating
By using this function you can choose 4 types of fan speed operating. Browse through this menu by the
pressing [Up] and [Down] keys - the display shows step by step the following messages: "HIGH, reG,
Lo.HI, Lo.OF". Press [Enter] if you wish to select one of them or [Mode] to cancel and return to the menu.
- high speed of the fans
The cooling fans work on max. speed (max. cooling).
- continuous controlling of the fan speed
The fan automatically raises its speed in order to control inside temperature of the lighting, if the
temperature inside increases about certain level (the low fan speed reduces the cooling of the
lighting). This cycle can repeat several times until the temperature inside is on a suitable level.
- low/high speed of the fan operating
The fan keeps the adjusted low speed until the temperature exceeds max. inside temp. of the
fixture, then the CC-200 automatically switches from low to high fan-speed.
- low speed / switch off the lamp operating
The fan keeps the adjusted low speed until the temperature exceeds max. inside temp. then the
CC-200 automatically switches off the lamp.
34

Publicité

Table des Matières
loading

Table des Matières