SAFETY
l Never use the generator to power medical support equip-
ment.
l Never expose the generator to rain, snow, water spray,
or standing water while in use. Store and operate the unit
in a dry or covered (but not enclosed) location.
l Do not let children or untrained individuals operate the
generator.
l Keep children, bystanders, and pets a minimum of 10 ft.
away from a running generator.
l Maintain Safe Distance. While operating and storing, keep
at least five feet of clearance on all sides of the generator,
including overhead. Turn the unit off and allow it to cool
a minimum of 30 minutes before storage. Heat created
by the muffler and exhaust gases could be hot enough to
cause serious burns and/or ignite combustible objects.
l Do not operate the unit in areas where combustible or
hazardous materials are stored including gasoline and
natural gas filling stations.
l Do not operate the generator while barefoot, with wet
hands or feet, while standing in water or in wet conditions.
l Do not use this unit when you are tired or under the in-
fluence of drugs, alcohol, or medication.
l Burn Hazard. Do not touch hot surfaces.
l Do not contact the muffler or engine. They are very HOT
and will cause severe burns. Do not put body parts or any
flammable or combustible materials in the direct path of
the exhaust.
l Keep hands, fingers, feet, and other body parts away
from all moving parts of the generator.
l Do not connect worn or damaged electrical cords to the
generator. NEVER touch frayed or exposed wires.
l Do not operate the generator on an incline. The unit should
always be placed on a flat stable surface.
l Check the physical condition of the product prior to each
use. Look for loose bolts, fluid leaks, and other signs of
wear. Replace all damaged items. For replacement parts
or assistance, contact our customer service team.
l For optimal performance, use the generator in tem-
peratures between 23°F (-5°C) and 104°F (40°C) with a
maximum relative humidity of 90%.
l Before starting the generator, check all fluids (oil and
gasoline).
l Do not remove the oil dipstick or fuel cap when the gen-
erator is running.
l Securely tighten the oil dipstick after adding oil and the
fuel cap after adding gasoline.
l Avoid skin contact with engine oil or gasoline. Wear pro-
tective clothing and equipment. Wash all exposed skin
with soap and water. Prolonged skin contact with gasoline
or engine oil may cause severe skin irritation and other
adverse reactions.
l Generator's vibrate and bounce during normal operation.
Check the generator and all of the cords connected to it
for any damage that may have resulted from the vibration.
Replace or repair damaged items as needed. Do not use
the generator or any items that show signs of damage.
6 | English
l All electrical tools and appliances operated from this
generator must be properly grounded by use of a third
wire or be double-insulated.
l Before transporting the generator, disconnect the spark
plug boot, drain the fuel tank and properly restrain the
unit.
l Fuel or oil may leak from the generator during transport.
Place a towel, plastic sheet, or absorbent pad beneath
the unit to protect your vehicle.
l To prolong the life of this product, follow the instructions
in the Maintenance section of this manual.
l Replace damaged or worn items with recommended
or equivalent replacement parts. Using an incorrect or
incompatible part might create a hazard that could result
in serious personal injury.
l Always remove any tools or other service equipment
used during maintenance away from the generator before
operating.
GROUNDING
See Figure 3.
WARNING
ground the generator can result in electric shock.
NOTICE
Only use grounded 3-prong extension
cords, tools, and appliances, or double-insulated tools
and appliances.
The generator neutral is bonded to the frame. There is a
permanent conductor between the generator (stator wire)
and the frame. If this generator will be used only with cord
and plug equipment connected to the receptacles mounted
on the generator, National Electric Code does not require
that the unit be grounded. However, other methods of using
the generator may require grounding to reduce the risk of
shock or electrocution.
Before using the ground terminal, consult a qualified electri-
cian, electrical inspector, or local agency having jurisdiction
for local codes or ordinances that apply to the intended use
of the generator.
DISCONNECTING THE BONDED NEUTRAL
See Figure 3.
The bonded neutral should only be removed under specific
circumstances. Consult a qualified electrician to determine
if circumstances require disconnecting the bonded neutral.
l Remove the alternator cover.
l Remove the green/yellow bonded jumper wire from the
ground bolt and unmarked terminal connection. Reinstall
the bolts and tighten securely.
l Keep the bonded jumper wire in a secure location so that
the generator can be returned to the original configuration.
NOTICE
Apply a new "NEUTRAL UNBONDED"
Label over the "NEUTRAL BONDED TO FRAME"
label on the front of the control panel.
Shock hazard. Failure to properly