OPERATION
DATA CENTER
See Figure 22.
Push the mode button to cycle through the data display
modes.
Voltage: Displays current voltage output.
Frequency (Hz): Displays power output frequency in Hertz.
Lifetime Hours: Displays the lifetime run hours.
Run Time/Maintenance: Displays current run time. Resets
to zero when shut down. Maintenance reminder displayed
when required.
Maintenance Codes:
P25 – Change engine oil
P50 – Clean air filter, Change engine oil
P100 –  Change engine oil, clean air filter, replace fuel
filter
PAIRING THE KEY FOB
See Figures 23 - 24.
l Bring the key fob in range of the generator.
l Ensure the battery is connected and the fuel selector
switch is in the FUEL OFF position .
l Push the battery switch to the ON position.
NOTE: When battery power is available, the battery indi-
cator light will illuminate and the LED around the engine
start/stop button will illuminate solid green.
l Press and hold the engine start/stop button for 10 sec-
onds until the LED around the button flashes green, then
release it.
l Press and hold the start button on the key fob for one
second, then release it.
•  If the key fob paired successfully, the LED around the
engine start/stop button will turn solid green.
•  If pairing was unsuccessful, the LED around the en-
gine start/stop button will continue flashing green. Wait
several seconds, then make a second attempt. If the
second attempt fails, turn the battery switch to the OFF
position, wait several seconds and repeat the process.
If subsequent attempts fail, turn the battery switch to
the OFF position and contact customer service.
l After the key fob is successfully paired to the generator,
turn the battery switch to the OFF position.
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated running
watts during the first five hours of operation.
Use supplied oil until first recommend oil change. Do not
use full synthetic oil during break in period. Full synthetic oil
may prevent proper breaking and seating of the piston rings.
Vary the load occasionally to allow stator windings to heat
and cool and help seat the piston rings.
24 | English
FIG. 22
A
C
A - Voltage
B - Frequency
C - Lifetime Hours
D - Run Time/Maintenance Reminder
E - Mode Button
FIG. 23
D
A - Red LED
B - Start Button
C - Stop Button
D - Key Fob
FIG. 24
A
A - Fuel Selector Switch
B - Engine Start/Stop Button
C - Battery Indicator
D - Battery Switch
E
B
D
A
B
START
C
STOP
D
B
C

Publicité

loading