Please clean up the thread
before installation!
Similar
pictures
Please seal the plug!*
No.
Description
1
Plug 1
1/2"
2
Plastic rosette sleeve cap
3
Insulation
4
Sleeve cap
Height adjustable feet (M12)
5
Height adjustable feet (M10)
Important maintenance notice
The magnesium anode must be replaced every 2 years. The anode is checked
according to the state of the art, at least by visual inspection, and must be
carried out annually. If it is heavily used, it may have to be changed beforehand
(annually). Control and exchange are to be evidenced by documentation. In the
event of a complaint, reports and the purchase invoice must be presented. The
DIN 4753 must be observed.
Installation / commissioning
Installation / commissioning
Maintenance
Maintenance
Maintenance
Maintenance
Maintenance
Maintenance
52
I N S T A L L A T I O N
A C C E S S O R I E S
1
Similar
pictures
Attention!!!
The enclosed O-ring
is not suitable for the
metal plug.
CAUTION
Without regular anode maintenance, the warranty is void
date
next appointment
done on
next appointment
done on
next appointment
done on
Similar pictures. Subject to technical changes and changes to content, misprints and errors.
2
3
signature
signature
signature
signature
5
Screw in feet (pos. 5) into
the suited threads
* The thread of the plug
(pos. 1) must be sealed
with a sealing that is
4
allowed for the usage
with sanitairy/drinking
water! The use of an
o-ring only is not
sufficient!