2.12
top exit
WARNING
!
•
Failure to install the cover plate and gasket will cause the appliance to function improperly and can cause
injury or property damage.
This appliance has been factory shipped as a top vent.
Remove the safety barrier and glass door (see "safety barrier & door removal/installation" section).
A.
Remove the contents from the firebox and set aside.
B.
You will need the exhaust and air inlet collar.
To ease assembly, remove the 4 hex head screws,
C.
securing the deflector from inside the top front of the
firebox (Fig. 1).
Remove the 1 1/2" (38.1mm) thick batt of insulation and
D.
discard (Fig. 2).
Place the 7" (177.8mm) intake collar and gasket onto the top of the appliance and secure using 4 screws
E.
(Fig. 2).
TIP: The manual baggie supplies the gasket and screws (packaged in another separate
baggie).
From inside the firebox, install the 4" (101.6mm) exhaust collar with gasket up through the top of the
F.
firebox, and secure with the the 4 hex head 3/4" black screws supplied in the manual baggie.
note:
Do not overtighten. The gasket needs only to be snug against the firebox.
Reinstall the top deflector, log set, glass door, and safety barrier.
G.
INTAKE
COLLAR
GASKET
1 1/2" INSULATION BATT
FIG. 1
OUTER
COVERPLATE
GASKET
venting requirements
DEFLECTOR
DÉFLECTEUR
Exhaust Collar
Fig. 2
W415-2944 / B / 05.22.24
EN
Fig. 3
27