• Check the device for signs of wear and tear or damage. If the de-
vice is damaged or you have any doubts, do not use it and con-
tact your retailer or Customer Services at the address provided.
• The manufacturer is not liable for damage resulting from improp-
er or incorrect use.
• Before use, check whether the light source is securely inserted.
• Protect the device from dust, dirt, sunshine and moisture.
6.2 Unpacking and setup
 WARNING
• The device should not be laid flat or positioned at an angle.
• Always ensure that your device is securely positioned on a level
surface.
• The minimum distance between combustible objects and the
infrared lamp must not be less than 1 metre.
• Ensure that the device is not placed on flammable items such as
tablecloths or carpets.
• Do not bring items that are highly flammable or likely to melt into
proximity of the device.
• Do not hang the device from the wall or the ceiling.
• Do not use the device outside.
• Protect the device from strong impacts to avoid the risk of dam-
aging the lamp. This also includes setting the device up in a
rough manner.
• Unwind the mains cable fully.
NOTICE
Avoid knocks to the device during use and during the cooling o
period, as these can lead to the infrared lamp being damaged.
Place the device on a stable, even surface.
6.3 Preparation for treatment
1. Position yourself in front of the device so that you can relax and
enjoy the treatment of the a ected part of the body.
2. Align the device correctly by tilting the infrared lamp towards the
part of the body requiring treatment. The distance between the
body part and the infrared lamp is generally determined based
on individual sensitivity to heat and the type of treatment being
performed.
3. Select the distance to the device such that the heat always feels
pleasant on the skin. If the heat feels too warm on your skin, move
away from the device.
4. Always use the supplied protective eyewear during usage. The pro-
tective eyewear corresponds to the requirements of EN 171:2002
and serves to protect the eyes.
 WARNING
Never look directly into the infrared light without protective eyewear.
Do not use the device continuously for longer than 15 minutes – risk
of overheating! Allow the device to cool before using it again.
6.4 Treatment duration
 WARNING
Risk of burning: Before switching on the device, remove metallic
objects from the area to be treated, such as belt buckles, necklaces,
bras, jewellery or piercings, as these can heat up significantly.
We recommend selecting a short radiation time at the start. Even
when the device is used correctly, some people may still experience
a hypersensitive (e.g. severe reddening, blistering, itchiness, heavy
sweating) or allergic skin reaction.
If symptoms are not relieved after 6 to 8 applications, stop using the
device and consult your doctor.
7. USAGE
7.1 Starting use
 WARNING
Always use the enclosed protective eyewear
Monitor the area of the body being irradiated and the reaction of the
skin regularly. Should signs of hypersensitivity or allergic reaction
occur, cease radiation immediately and consult a doctor. Never look
directly into the switched-on infrared heat lamp.
Risk of burns! During treatment, never touch the hot filter
disc
2
.
1. Hold the protective eyewear to your eyes and pull the rubber band
over your head. You can adjust the elastic band individually.
2. Insert the mains plug into a suitable socket.
3. Press the ON/OFF
vice switches on automatically. The remaining time display
shows "00"
4. Use the time selection button
duration (1 to 15 minutes). The set treatment duration is displayed
in the remaining time display
of treatment during treatment using the time selection button
5. After the set treatment duration has elapsed, the device switches
o automatically. To stop the treatment early, press the ON/OFF
switch
. You can now remove the protective eyewear.
3
6. Pull the mains plug out of the socket. Allow the device to cool
down.
7.2 After treatment
NOTICE
• The fan will continue running for 5 minutes after you have
finished using the device in order to cool it down. Please do
not unplug the device during this period.
• Once the cooling period has finished, the fan will switch itself o .
Pull the mains plug out of the socket.
• If the device is warm, do not cover it or pack and store it.
8. CLEANING AND MAINTENANCE
8.1 Cleaning
 WARNING
The device must be switched o , disconnected from the mains and
allowed to cool down fully each time before cleaning.
NOTICE
• Make sure that no water gets inside the device!
• Do not clean the device in the dishwasher.
The device may be cleaned with a damp cloth. Do not use any sol-
vent-based cleaning products. The device should be cleaned after
each use.
Clean the protective eyewear from time to time. Use a slightly damp,
soft cloth to clean it. Do not use any sharp or abrasive cleaning
products.
8.2 Replacing the infrared lamp
Please note that only an infrared lamp of the same type may be used
as a replacement for a defective infrared lamp.
 WARNING
Risk of electric shock!
• Unplug the mains cable from the socket before replacing the
infrared lamp!