Product information
Description
Max surface temperature in Dust at-
mosphere
Explosion prevention guidelines
Cleanliness
Make sure the product is kept clean from dust and dirt to prevent increased bearing and surface tem-
perature.
If using a silencer: Make sure a silencer with a filtering effect at the air outlet is installed to prevent
any friction-heated particles entering into the surrounding atmosphere.
Usage
Make sure the product is earthed to the equipotential bonding system of the workshop, for example
through accessories such as hoses and air-pressure connections.
It is the responsibility of the user to make sure that the product and all possible accessories, such as
wrenches and air connections, conform to the national safety regulations for equipment used in po-
tentially explosive areas.
8
EN
Value
© Atlas Copco Industrial Technique AB - 9836 9861 00
LLA2500-L-ATEX
Definition
Example temperatures:
T85°C
T110°C
T120°C
T125°C
T240°C