Operating Instructions
Automatic closing:
Automatic closing deactivated.
Automatic closing without shortening delay:
After a delay of 1 min. the door closes. If the door comes across an obstacle,
automatic closing is interrupted after 5 unsuccessful attempts. The door then
has to be guided to the lower end position via the buttons on the control panel
or conducted equipment.
Automatic closing with delay shortened to 3 sec.:
After a delay of 1 min. the door closes. This time is cut to 3 sec by passing the
light barrier. If the door comes across an obstacle, automatic closing is inter-
rupted after 5 unsuccessful attempts. The door then has to be guided to the
lower end position via the buttons on the control panel or conducted equip-
ment.
Automatic closing with delay shortened to 15 sec.:
After a delay of 1 min. the door closes. This time can be cut to 15 sec. by pass-
ing the light barrier. If the door comes across an obstacle, automatic closing
is interrupted after 5 unsuccessful attempts. The door then has to be guided
to the lower end position via the buttons on the control panel or conducted
equipment.