Factory settings

Factory setting for dead man's operating mode:
ON
DIP
1
4
2
3
5
6
7
8
Factory setting for automatic operating mode
(only with safety edge evaluator):
ON
DIP
1 2 3
1
2
3
4
5
6
7
8
Operating mode
Setting mode:
End position recognition and running time monitoring are deactivated. The
control does not remove the power from the tubular motor when an end posi-
tion has been reached. Thus, the door system can be adjusted under power.
This means that the door system immediately follows the settings of the limit
switch. To remove power press the STOP button.
Attention
The setting mode is suitable for tubular motors with mechanical limit switch-
ing.
When all settings have been completed, DIP switch 1 has to be set to OFF
(door mode). Operation in setting mode is not permitted!
Door mode:
The control device is on standby. End position detection and running time mon-
itoring have been activated.

Configuration

With the 8 DIP switches you can configure the
control according to your own requirements:
• Operating mode
• Safety edge system
• Yard light or advance warning lamp
• Automatic closing
DIP-switch