Operating Instructions
Mains plug
Power is cut off from the control by removing the plug from the mains. Movement of the
door is no longer possible.
Caution
Work at electrical installations should always be carried out by a qualified
electrician.
Status display
The status display of the control shows the current state of the control device and is
located above the UP button.
Abbreviations
USA Safety edge system
Detector of the main safety edge arrestor. It is designed to recognise obstacles while
the door is closing.
LS Photo cell
The light barrier functions as object protection for monitoring the door system and for
controlling automatic closing.
AWZ Automatic closing:
The door automatically closes after the programmed automatic return time.
20
Device Overview
:
:
Status display
„UP" button
„STOP" button
„DOWN" button
Radio hand transmitter
Mains plug