CONNECTIONS

Chlorine Amperometric
Probe

DEFAULT SETTINGS

PASSWORD = Not programmed
Delay On: 0 minutes
Enable (optional): active
Broken Hose (optional): active
TAL: 0 unit (disabled)
Flow (optional): Normally Open
 Dosing: Proportional
 SetP (setpoint): 1.20ppm
 T.MAX (maximum threshold): 0.20ppm
 Flow.Max (maximum flowrate): 80%
 Delay On: 3 sec (0-999sec)
WARNING!! The factory parameters shown are also valid for the pump version combined with the potentiostatic chlorine
probe 0-2.0ppm. In the application of water purification, the desired chlorine values are much lower. So in case of
restoration of the factory parameters the pump must be reprogrammed with the desired chlorine values!!!

DEFAULT SETTINGS RESTORE

3sec
Rev 1.1
Chlorine Potentiostatic
Probe
Keep pushing for 3 seconds the ENTER / MENU button to
enter into the programming menu.
Move the cursor > to Utility by pressing ▼. Push ENTER
button to enter the submenu.
Push ▼ button to move the cursor to "Reset".
Push ENTER button to confirm.
By pushing the ▼ button choose "YES" to confirm and push
ENTER button.
Choose to restore the "Programming Parameters". Press
ENTER.
Automatically the pump restores the factory settings.
Press the ESC button for 3 seconds to exit programming.
Cod. 00.009.127
A - Power cable, 90-250V-50-60Hz
B - Enable input (dosing consent)
(110Vac; 230Vac; upon request 24V).
OPTIONAL
C - connector for CL probe.
D - Level probe connector (3 and 4 contacts).
OPTIONAL.
E - Alarm output connector (3 and 4 contacts).
( 5A 250Vca/30Vdc) NORMALLY OPEN.
OPTIONAL
F - Flow sensor connector (3 and 4 contacts).
OPTIONAL
G – ON_OFF switch. OPTIONAL