ENGLISH

DESCRIPTION OF CHARACTERISTICS AND OPERATION

The "VP2-HT CL" dosing pumps series are ideal for dosing chlorine in small, medium and large pools. The version for
potentiostatic chlorine probe 0-2.00ppm is ideal for water purification.
They can operate in Manual, ON-OFF and Proportional mode and the flowrate is adjustable from 10% to 100% of the
maximum flowrate. They can adjust the flowrate by varying the rotation speed of the roll holder.
In standard version it is possible to set a "Delay on" switching on that allows to stabilize the measurement before dosing.
It is possible to set an overdose alarm ("TAL").
Optionally, these pumps can be equipped with a peristaltic tube break sensor which, in case of chemical leaks, blocks the
dosage and they can optionally have a relay output, configurable for the repetition of an alarm (for example: flow alarm,
level alarm, peristaltic hose breakage, etc).

FRONT PANEL DESCRIPTION

1.Display LCD 16x2 characters LCD display backlight
2.Green Led: ▪ fix = PUMP ON
▪ blinking = PUMP IN ALARM
3.Red Led: indicates the injections of chemical dosing
4.ENTER/MENU button : ▪ allows to enter in programming

GENERAL FUNCTIONS

- REAL TIME CL MEASURE
- REAL TIME FLOW RATE% VISUALIZATION
- 3 POSSIBLE TYPES OF DOSAGE: MANUAL, ON / OFF, PROPORTIONAL
- MENU IN 4 LANGUAGES: ITALIAN, ENGLISH, FRENCH, SPANISH
- POSSIBILITY TO INSERT A PASSWORD
- DELAY ON SWITCHING
- OVER DOSAGE TIME ALARM
- PRIME BUTTON
- ALARM RELAY (DRY CONTACT) OUTPUT FOR REPEATING ALARMS
- RESTORATION OF DEFAULT PARAMETERS AND FACTORY CALIBRATION
- DOSAGE STOP (STAND_BY)
- WATER FLOW SENSOR ALARM
- CONTROL OF PRODUCT END LEVEL
- ENABLE INPUT SIGNAL
- HOSE BREAKAGE SENSOR
- OVER AND UNDER RANGE OF THE MEASURE VISUALIZATION
Rev 1.1
▪ saves the changes
Cod. 00.009.127
5. ESC/SBY button: ▪ allows to exit from the menu
▪ puts the pump in stand_by mode
6/7. ▲▼ buttons : ▪ allow to navigate through the menu
▪ allow to modify the parameters values
8. Prime button: ▪ allows to prime the pump