13. Troubleshooting
Fault
Possible cause
• No supply voltage.
The compressor
does not start.
• Insufficient supply voltage.
• Outside temperature is too low.
• Motor is overheated.
• The non-return valve (19) leaks.
The compressor
starts but there is no
pressure.
• The seals are damaged.
• The drain plug for condensation water (10) leaks.
• The hose connections have a leak.
The compressor
starts, pressure is
• A quick-lock coupling has a leak.
shown on the pres-
sure gauge, but the
tools do not start.
• Insufficient pressure set on the pressure regulator (5).
42
GB
Remedy
• Check the supply voltage, the power plug and the
socket-outlet.
• Make sure that the extension cable is not too long.
Use an extension cable with large enough wires.
• Never operate with an outside temperature of below +5° C.
• Allow the motor to cool down. If necessary, remedy
the cause of the overheating.
• Contact your local service centre. Every attempt to carry
out a repair, can be dangerous if it is not done by skilled
personnel.
• Check the seals and have any damaged seals re-
placed by a service center.
• Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
• Check the compressed air hose and tools and replace
if necessary.
• Contact your local service centre. Every attempt to carry
out a repair, can be dangerous if it is not done by skilled
personnel.
• Increase the set pressure with the pressure regulator.