Determination
of
F.A.D
The F.A.D
is
measured by filling a bottle of min.
5
Hrs.
or
max.
10
ltrs. (water
volume),
Prescribed
filling
pressure
:
200 bar/2860 psig.
Instructions:
Open bottle valve, to ensure
that
the
bottle is
empty.
Connect
bottle
to the closed
filling
valve.
Start
compressor and
when
It
has
reached 200 bar/2860 psig
open filling valve.
Note
the
exact
filling
time taken
to
reach
filling
pressure,
(convert
seconds
to
decimal
minutes).
Calculation
of
F.A.D
Cyltnder
volume (hrs)
x filling
pressure {bat)
-
--
"".:'.'.'."'"-'C"""--:--77--- - -
F.A.0.
(ltrS/min)
filling time (min)
Cylinde<
volume
(f')
x filling pressure
(bar)
filling rime (min)
6
F.A.D.
(c
f
m)
Determination du
debit
On determine le debit
en
remplissant une bouteille
d'une capacite
minimale de
5
litres
ou
maximale de
10
litres.
Pression de remplissage prescrite:
200
bar
Instructions:
O~ir le
robinet
de
la
bouteille
atin de
la vider.
Brancher
la
bouteille
au
robinet
de remplissage
ferme.
Mettre
en
marche le compresseur
et
ouvrir
le
robinet de remplissage des
que
la
pression
a
atteint 200 bar.
Chronometrer
le
temps exact
de
remplissage et
calculer le debit salon la formule ci-dessous
(convertir les secondes
en
minutes
decimales).
Calcul du debit
Cap.
de
la bout
(I) x
Press.
de rempl.
(bar)
---,,----,---,,----,-77-- •
Debit
(Vmln)
T
• ~
de
remplissage
{min)