3. Use a paint brush to apply the solution onto the seal between the regulator and the gas cylinder. Visually inspect for
streams of bubbles coming from a defect or break in the seal.
NOTE: If a leak appears, repeat gas cylinder installation procedure, but do not over-tighten. Hand-tighten
only. Repeat leak test after re-installation to ensure seal is secure.
IMPORTANT: Do not use the gas smoker if you detect a gas leak that cannot be corrected by using the leak
test procedure. Contact your local Fire Department or Customer Care for alternative measures of testing to
ensure proper precaution.
FIRST USE – CURING & BURN-OFF
Before using your smoker for the first time with food, it is important to complete a burn-off to cure the interior and exterior
finish of your unit. Start the smoker and operate at any temperature over (177°C / 350°F) with the cabinet door closed for 30 to
40 minutes to burn-off the unit and rid it of any foreign matter.
IMPORTANT: Curing your smoker is important for its long-term operation and care. If the burn-off is not
performed, the exterior finish will not set properly, as well as a paint odor can impart unnatural flavors
onto your first prepared meal.
LIGHTING PROCEDURE
1.
Verify that all control knobs are turned to the OFF position.
2. Connect LP gas cylinder as per instructions. Turn LP gas tank valve to OPEN.
3. Note the indicator marker on the control knob. Push and hold down the control
knob on the smoker and turn 90 degrees (or 1/4) counter-clockwise SLOWLY (2 to
3 seconds) to HIGH. You should hear a "click" sound to indicate a spark from the
igniter, and look for flame to ensure the burner is lit. If it does not, repeat up to
three times.
4. If ignition does not occur in 5 seconds, turn the control knob to OFF, wait 5 minutes and repeat lighting procedure. If the
above points do not work, follow Manual Lighting Procedure instructions .
5. After the burner has caught fire, you are ready to enjoy your smoker at your desired temperature!
IMPORTANT: If the burner goes out during operation, turn the control knobs to the OFF position. Wait
five minutes before attempting to relight to allow any accumulated gas to dissipate.
IGNITER FAILURE PROCEDURE
If for any reason your igniter fails after three of four attempts, check the following steps, or start your smoker
using the manual method.
1.
Ensure the control knob is turned to the OFF position. Allow any accumulated gas to dissipate.
2. After five minutes, check the following:
Visually confirm that the igniter is working by pushing the igniter button and looking at the igniter tip for a
spark. If no spark, adjust the distance between the igniter (electrode) tip and burner to 4.5 mm (3/16 in).
Visually confirm that the burner tube and portholes are not obstructed. If blocked, follow Care & Maintenance
instructions .
3. If the above points do not work, follow Troubleshooting instructions .
Slight Yellow
Flame
Slight Blue
Burner
Dark Blue
12