Connection plan
AP.4.017722
Pin 7
Not connected
Black (BK)
Leave unconnected
Pin 8
Control
Grey (GY)
You can retract and extend the cylinder via the two wires. By applying a voltage, for example the supply voltage
of the cylinder, to the red wire (pin 9), the cylinder retracts. The definition of the wires is as follows:
Pin 9
Red (RD)
Voltage level
*with respect to GND (pin 1)
Pin 10
Not connected
Violet (VT)
Leave unconnected
Pin 11
Gray-Pink
(GYPK)
Pin 12
Red-Blue (RDBU)
Example
Connection example – drive
DC PSU
AP.4.017722
Version 1.2
Continued from previous page
Pin 8 (GY):
Extend
Pin 9 (RD):
Retract
8.0 ... 30.0 VDC*
Drive:
0.0 ... 0.8 VDC*
Stop:
Extend
Retract
RD
RD
+
-
BN
M12power
GY
M12 signal

Publicité