Connection plan
AP.4.017713
Connection plan AP.4.017713
Cable
Pin assignment M12power (3-pin)
*** Supply voltage ***
Pin
Description
Functional earth
Pin 1
Brown (BN)
DC power supply
Pin 3
Red (RD)
Pin 4
Black (BK)
AP.4.017713
Version 1.1
M12power
(top view)
3 (RD)
DC supply voltage
The power cable is used to supply the cylinder with power
from the DC supply voltage (DC PSU).
The brown (BN) wire is to be connected to earth.
Control
The cylinder extends or retracts according to the polarity of
the power supply.
Red
Retract
Minus
Extend
Plus
1 (BN)
4 (BK)
Black
Plus
Minus
Pwr