Télécharger Imprimer la page

Phoenix Mecano LD1000E Instructions De Montage page 37

Masquer les pouces Voir aussi pour LD1000E:

Publicité

Connection plan
AP.4.017714
Pin assignment M12 Signal (5-pin)
*** Communication & control plug ***
Pin
Description
Pin 1
Control
Brown (BN)
You can retract and extend the cylinder via the two wires. By applying a voltage, for example the supply voltage
of the cylinder, to the brown wire (pin 1), the cylinder retracts. The definition of the wires is as follows:
Pin 2
Voltage level
White (WH)
*to GND (Pin 5)
Pin 3
Not connected
Blue (BU)
Leave unconnected
Pin 4
Black (BK)
Pin 5
GND of the linear drive
Grey (GY)
Low-resistance GND connection of the linear drive.
Do not connect to the supply voltage!
Example
Connection example
DC PSU
AP.4.017714
Version 1.1
Pin 1 (BN):
Retract
Pin 2 (WH):
Extend
8.0 ... 30.0 VDC*
Drive:
0.0 ... 0.8 VDC*
Stop:
Extend
Retract
BN
BN/BK1
+
-
BU/BK2
GNYE
Power
cable
WH
M12 signal
In

Publicité