Télécharger Imprimer la page

Phoenix Mecano LD1000E Instructions De Montage page 63

Masquer les pouces Voir aussi pour LD1000E:

Publicité

Connection plan
AP.4.017722
Connection plan AP.4.017722
Pin assignment
M12power
(top view)
3 (RD)
Pin assignment M12power (3-pin)
*** Supply voltage ***
Pin
Description
Pin 1
Functional earth
Brown (BN)
Pin 3
DC power supply
Red (RD)
Pin 4
Black (BK)
AP.4.017722
Version 1.2
M12-12pol
(top view)
2 (BU)
1 (BN)
3 (WH)
4 (GN)
11 (GYPK)
4 (BK)
DC supply voltage
The power cable is used to supply the cylinder with power from
the DC supply voltage (DC PSU).
Connection
Connect the black wire to minus (0V) and the red wire to plus.
The permissible voltage can be found on the type plate.
The brown (BN) wire is to be connected to earth.
10 (VT)
1 (BN)
9 (RD)
8 (GY)
12 (RDBU)
5 (PK)
7 (BK)
6 (YE)
Pwr

Publicité

loading