Connection plan
AP.4.017719
Connection plan AP.4.017719
Pin assignment
Power cable
(sketch)
BU
(BK2)
2
Cabel: 3 G 1.5mm
2
(Cabel: 3 G 2.5mm
)
Power cable
*** Supply voltage ***
Wire
Description
Functional earth
2
1.5mm
:
Green-Yellow
(GNYE)
2
2.5mm
:
Green-Yellow
(GNYE)
DC power supply
2
1.5mm
:
Brown (BN)
2
2.5mm
:
Black 1 (BK1)
2
1.5mm
:
Blue (BU)
2
2.5mm
:
Black 2 (BK2)
AP.4.017719
Version 1.2
M12-12pol
GNYE
(top view)
(GNYE)
3 (WH)
4 (GN)
BN
11 (GYPK)
(BK1)
DC supply voltage
The power cable is used to supply the cylinder with power
from the DC supply voltage (DC PSU).
2
Wiring with 1.5mm
Connect the blue wire to minus (0V) and the brown wire to
plus. The permissible voltage can be taken from the type
plate.
2
Wiring with 2.5mm
Connect black wire 2 (BK2) to minus (0V) and black wire 1 (BK1) to plus. The per-
missible voltage can be taken from the type plate.
General
The green-yellow (GNYE) wire is to be connected to the ground.
10 (VT)
1 (BN)
2 (BU)
5 (PK)
7 (BK)
6 (YE)
9 (RD)
8 (GY)
12 (RDBU)