MAINTENANCE (cont.)
SPARK PLUG
CLEAN AND REGAP EVERY 600 HOURS OF OPERATION OR
REPLACE AS NEEDED.
CLEAN AND REGAP EVERY 600 HOURS OF OPERATION OR
REPLACE AS NEEDED.
Spark Plug
Ignitor Wire
Burner Head
Figure 15 – Spark Plug Replacement
(For Models CP125AK and CP170AK only)
- Remove upper shell (See Air Intake Filter, page 12).
- Remove fan (See Fan Blades).
- Remove ignitor wire from spark plug.
- Remove spark plug from burner head using medium Phillips
screwdriver.
- Clean and regap spark plug electrodes to
.140" (3.5 mm) gap.
- Reinstall spark plug into burner head.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.
Bracket Burner
Bracket Spark
Figure 16– Spark Plug Replacement
(For Model CP210AK only)
- Remove upper shell (See Air Intake Filter, page 12).
- Remove fan (See Fan Blades).
- Remove ignitor wire from spark plug.
- Remove spark plug from bracket spark using medium Phillips
screwdriver.
- Clean and regap spark plug electrodes to
.140" (3.5 mm) gap.
- Reinstall spark plug into bracket spark.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.
Spark Plug
PHOTOCELL
Side Cover
Power
Switch
Screw
PhotocellWire
Bracket
Install Photocell
Incorrect
Correct
Figure 17 – Photocell Replacement
CLEAN PHOTOCELL ANNUALLY OR AS NEEDED.
- Remove upper shell (See Air Intake Filter, page 12)
- Remove fan (See Fan Blades)
- Remove photocell from its mounting bracket.
- Clean photocell lens with cotton swab.
TO REPLACE: Remove side cover near power switch.
- Disconnect wires from power switch and remove
side cover.
- Disconnect wires from circuit board and remove photocell.
- Install new photocell and attach wires to circuit board.
- Replace switch wires to power switch and side cover.
- Replace fan and upper shell.