Display of operating state
The following displays and controls are provided on
the control unit:
Table 2: Displays and controls
Element
Status
Off
Lights up
green
Flashes
green
Lights up
orange
Status LED
Lights up
red
Flashes
green/red
Press
button for
< 5 s
<Test>
button
Press
button for
> 5 s
Off
4)
On
3)
Buzzer
Beeps
every
second
27021608492248843 © 04-2024
971.558.00.0(03)
Meaning
• No operating voltage
• Normal operation
• Solenoid valve open
• Warning, diagnose
with Geberit Control
app
• Addressing via
1)
GEBUS pending
• Malfunction, diagnose
with Geberit Control
app
• Basic settings not
configured
• Localisation of the
1)
hygiene flush unit
• Solenoid valve test:
Solenoid valves open
one after the other for
5 s after releasing the
button
• When the solenoid
valve test is active:
Cancel test
• In the event of an
active malfunction:
suppress buzzer
• Identification of the
2)
hygiene flush unit
• Pair with the Geberit
Control app
• Normal operation
• Buzzer deactivated
• Malfunction, diagnose
with Geberit Control
app
• Localisation of the
1)
hygiene flush unit
1) Only when connected to GEBUS → see Geberit
Connect system manual
2) When the button is pressed, the hygiene flush unit is
highlighted in the Geberit Control app under
[My end devices].
3) The buzzer is deactivated ex works. It can be
reactivated in the Geberit Control app if required.
Serious faults such as backpressure are always
indicated by the buzzer.
4) The buzzer can be suppressed by pressing the
<Test> button.
Technical data
Operating voltage
Power consumption
Power consumption in
standby mode
Degree of protection
Flow pressure
Maximum cold-water
temperature
Flush performance per
solenoid valve
Wireless technology
Frequency range
Maximum output power
1) The Bluetooth® brand and its logos are the property
of Bluetooth SIG, Inc. and are used under licence by
Geberit.
12 V DC
7.2 W
1 W
IP45
0.1–10 bar
25 °C
4 l/min
Bluetooth® Low
1)
Energy
2400–2483.5 MHz
4 dBm