DNCM−...−POT
Set the connecting rod to dimension x.
(not required for DNCM−50−...−POT be
cause of the additional spacer).
With all DNCM−...−POT:
Place the coupling plate aA against the
eye nut 7.
Tighten the spacer 8 with clamping nut 9 on the piston rod (10 Nm)
whilst counter−pressing against the spanner flats 6.
With DNCM−32−...−POT:
Place the spacer aC together with the guide nut aD on the coupling plate aA.
Tighten the spacer aC with locking nut aB whilst counter−pressing against
the guide nut aD.
With all DNCM−...−POT:
Complete commissioning as described in the section Commissioning."
12
Accessories
Title
Non−return valves and flow−control valves
Clevis feet and flanges
Fastenings
Piston rod attachments
Couplings
Proximity switches
Fig. 20
28
Fig. 19
Type
See Products" catalogue
SME−8−... / SMT−8−...
Festo DNCM−...−POT 0608a English
X = min. 0.5
g