Télécharger Imprimer la page

Alecto SA241 Mode D'emploi page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

TECHNICAL DATA:
Working temperature ...................................................................................... 0˚C tot 40˚C
Power ............................................................................................................. 220-240V AC 50Hz + 9V DC Battery backup
Battery backup time
Power usage in standby ................................................................................. 18 µA max.
Power usage in alert ...................................................................................... 45mA max.
Sound level during alert .................................................................................. 85dB at a distance of 3m
Humidity .......................................................................................................... < 93%
Maximum link possible ................................................................................... 12 models at a maximum distance of 150M
This smoke detector can only be linked with other smoke detectors of the same model.
DECLARATION OF PERFORMANCE:
Is available at the following internet address:
http://DOC.hesdo.com/SA240_DOP_1.pdf
PROBLEM
No sound during test procedure
Note: Hold the test button at least 5 seconds
during the test.
The smoke alarm beeps every minute
The smoke alarm frequently gives a false alarm,
constantly gives a false alarm during cooking or
when showering.
If the 230V is not connected, the 9V battery will last
at least 1 year
SOLUTION
1. Remove the alarm to check if the battery is installed properly and on the right
polarity.
2. Clean the smoke alarm.
Replace the 9V battery
1. Clean the smoke alarm.
2. Move the smoke alarm to a different location.
17

Publicité

loading