Venting
1.
Shut off electric supplies to the heater.
2.
Turn the flow on (turn the hot water tap on) in order to vent the water installation
(for about 15-30 seconds), until the flow of water becomes constant and even.
3.
Switch on the electric supplies.
Configuration
Heating box size 15 kW
P
P
P
P
Heating box size 24 kW
P
7
P
P
P
Heating box size 27 kW
P
White square shows the
switch position.
The heater is factory set at NORMAL mode (30-60ºC). To use the heater for shower
purposes it has to be changed to SHOWER mode (30-55ºC). Change of the modes can
only be done by authorised service.
DE;EN;FR;IL -099C_f.1290
Notice! Configuration must be performed before initial
start-up when power supply is switched off. Set 2 (two)
switches at proper position to configure a heater. The
switches are located on electronic board. Each switch
has 4 (four) positions, they are described as
settings) and
F
(other settings). Switch on a power supply
to upgrade configuration. After you supply power to KDE5
a display will show: (PW...) - software version of control
panel, (MSP...) - software version of controller and the
value of rated power that has been set for the heater.
switches settings:
1, 2 - rated power of heater,
3, 4 - type of heating box,
switches settings
1, 2, 3 - do not change! keep factory settings,
4 - ON - blocks access to the heater's settings.
In this case in KDE 5, the display shows the desired
temperature value (which has been adjusted before
the heater is off), the heating icon and other possible
working characteristics.