IBERITAL
3.2. WATER SUPPLY CONNECTION
IMPORTANT
This equipment must be installed in accordance with applicable federal, state or local regulations.
The machine has a 3/8" water inlet for the water supply. The said inlet incorporates a stop tap to open or close the flow
of water (optional). Likewise, hoses are included. To be correctly installed, the mains water supply stop tap will have to
be connected to the previously mentioned inlet on the machine using one of these hoses, or similar.
3.3. CONNECTION TO THE POWER SUPPLY
IMPORTANT
This equipment must be permanently connected to the power supply.
The machine is equipped with elements and other electrical parts at 110 V, 220 V - 240 V depending on the version.
A switch must be installed, of a suitable calibre, between the permanent installation and the machine. The maximum
electricity consumption is indicated on the rating plate.
The earth cable must be connected to an efficient earth.
IMPORTANT
The machines can only be connected to 110 V, 220 V - 240 V depending on the version of the
machine.
3.3.1. Coffee machines with the CE marking
5-core machines
220 V - 240 V SINGLE PHASE WITH NEUTRAL WIRE (1-2-3 GROUP MACHINES)
Phase (R)
Neutral
The machine can be connected to power supplies with a single phase of 220-240 V. In this case, all the cables phase must
be joined Black, Brown and Grey, and then connected to the phase within the permanent electrical installation. The Blue
cable must be connected to the neutral wire. The Green/Yellow cable must be connected to the earth.
400 V THREE PHASE WITH NEUTRAL WIRE (1-2-3 GROUP MACHINES)
Phase (R)
Phase (S)
Phase (T)
Neutral
The machine can be connected to power supplies with three phases and a neutral wire of 400 V. In this case, the Black, Brown
and Grey cable must be connected one by one at each of the three different phases, and the Blue cable to the neutral wire. The
Green/Yellow cable must be connected to the earth.
102
Black
Brown
Gray
Black
Brown
Gray
Blue
Green/Yellow
220-240V
Blue
Green/Yellow
220-240V
INSTALLATION AND OPERATION MANUAL