Télécharger Imprimer la page

Autosen AL009 Notice D'utilisation page 46

Publicité

Les langues disponibles

Les langues disponibles

10.2.4 Hysteresis function
The hysteresis keeps the switching state of the output stable if the measured
value varies about the sensing range� The selected switch point [SPx] is the set
point� The reset point is automatically set above the selected switch point [SPx]
by the sensor� The nominal distance between switch-on pint and reset point is
the hysteresis, it is indicated in the data sheet� The hysteresis depends on the
reflectivity of the background�
Example Hno
1� For the output function [Hno] the output switches when the object approaches
and when the set point (A) is reached�
2� When the object is removed again, the output does not switch back before the
reset point (B) is exceeded�
The reset point (B) is above the set point (A)�
1
2
[SPx] = switch point; A = set point; B = reset point
If the output function [Hnc] has been selected, the set and reset points are
reversed� The output switches off when the object approaches� When the object is
removed again, the output switches�
46
A =[SPx]
A = [SPx]

Publicité