Background teach for hysteresis function OUT1 / 2
t51
Limit value at which the output with selected hysteresis function changes
its switching state (object nearer/farther than distance set)�
t52
[tS1] is only active if [OU1] = [Hno] or [Hnc]
[tS2] is only active if [OU2] = [Hno] or [Hnc]
→ 10.2.6 Background teach for hysteresis function OUT1 / OUT2.
Teach - Switch points for window function OUT1 / 2
tn1
Limit values at which the output with selected window function changes its
switching state (object present / not present between the distance "near"
tf1
and the distance "far")�
tn2
[tn1] = switch point "near" / [tF1] = switch point "far"�
[tn1] / [tF1] are only active if [OU1] = [Fno] or [Fnc]�
tf2
[tn2] = switch point "near" / [tF2] = switch point "far"�
[tn2] / [tF2] are only active if [OU2] = [Fno] or [Fnc]�
(→ 10.2.10 Teach - Setting of the switch point for window function OUT1
/ OUT2)
Setting of the fault suppression time for switching
dfo
outputs
This function suppresses brief saturation of the measuring element
(such saturation may result from direct reflection or strong fluctuations in
brightness)� During the set delay time, the latest valid value measured is
displayed, the output signals remain unchanged�
(→ 10.3.2 Setting of the fault suppression time for switching outputs)
Setting of the display
di5
2 settings can be selected:
[on], [OFF]
With the setting [OFF] the display is switched off automatically after 30
sec� Only the "power-on" LED remains active�
Each push of the button re-activates the display for 15 sec�
(→ 10.2.2 Setting the display)
Setting of the display unit
vni
Selection of the unit of measurement for [SP1], [SP2], [nP1], [nP2], [FP1],
[FP2]
Options: [mm], [Inch]
(→ 10.2.1 Selection of the display unit)
UK
41