1.

TECHNICAL DETAILS

GB
Power supply
Absorption
Motor power supply
Motor torque
Max load
Speed
Service life
Intermittence
Temperature
Degree of protection
Control panel
Radio frequency
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be guaran-
teed with the use of DITEC accessories and safety devices.
2.1 Standard installation references (fig. 1)
[1] Gearmotor (RADIUS1)
[2] Arms (RADIUSG)
[3] Guide (RADIUSG)
[4] Lock (RADIUSLOK)
[5] Automation profile (V1998N61)
[6] Block hook
[7] Automation lid (V1999N61)
[8] Control panel (RO2H)
3.
INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres (mm).
The installation sequence is illustrated in fig. 7.
3.1 Preliminary checks
Check the installation measurements A, B and C indicated in fig.
2, 3, 4.
Choose the most suitable type of arm.
-
RADIUSG for rigid door wing shutters (A = 155 max).
-
RADIUSG1 rigid door wing for shutters (A = 105 max).
-
RADIUSG2 for fractioned door wing shutters (fix the arm
resting sliding block [9] to the door wing, so that the latter is
not damaged by the arm during opening).
Note: the measurements are an indication and must be checked
during installation.
3.2 Installation of the profile
-
Cut the profile [5] at the dimension L-10 and drill as indi-
cated in fig. 5.
-
Insert the motor, block and control panel fastening nuts in
profile [5].
-
Fix profile [5] to the ceiling.
Note: leave the necessary gap to the side of the profile to pass
the power supply cable.
3.3 Motor, block and control panel installation
-
Fix the motors [1], the block [4] and the control panel [8]
as indicated in fig. 1, 3 and 4.
Note: pass the power supply cable to the side.
-
Assemble the arms [2] and fix them to the motors [1].
RADIUS - IP1862
RADIUS
230 V~ / 50-60 Hz
0,3 A
12 V= / 1,4 A
23 Nm
30 Kg (1 leaf)
12 s / 180°
2 = LIGHT
S2 = 7 min, S3 = 15%
-20 °C / +55 °C
IP44 (with aluminum profile)
RO2H
433,92 MHz
Note: do not tighten the screws, so that the arms can be
rotated manually.
-
Fix the guide [3] on the shutters.
Manually move the shutters and check that they open and
close correctly.
3.4 Block hook installation
-
Fix the block hook [6] to the shutter with motor M1 as
indicated in fig. 1 and 4, close to the side opposite the
hinges.
-
Check that the block [4] and related hook [6] are aligned
correctly.
-
Tighten all screws, except for the screws that secure the
arms [2] to motors [1].
3.5 Automation closure
-
Perform the electrical connections, the adjustments and
the start up.
-
Referring to fig. 6, cut the automation lid to size and drill
along the axis for the motor arms and blocking pin exits.
Note: the pre-drilled side lid can be used (RADIUST).
3.6 RADIUSB installation
The RADIUS motors can be built-in to the wall as indicated in
fig. 8.
The installation sequence is illustrated in fig.9.
-
Drill the wall Ø80 mm and insert the RADIUSB support
securely and in level.
Note: prepare the side channel for the wiring.
-
Fit the motor to the appropriate bracket and fix it inside the
RADIUSB support.
Note: pass the cables inside the arrangement.
-
Fix the lid of the motor to the appropriate bracket.
-
Assemble the arms [2] and fix them to the motors [1].
Note: do not tighten the screws, so that the arms can be rotated
manually.
-
Fix the guide [3] on the shutters.
Manually move the shutters and check that they open and
close correctly.
-
Connect the motors to the RO2H control panel with a
2x0.75 mm² cable (max. 10 m).
Note: the control panel can be inserted inside the CONT3 container.
Attention: the block is not foreseen for this type of installation.