TECHNICAL DETAILS

GB
Power supply
Absorption
Motor power supply
Motor torque
Speed
Max load
Max run
Service life
Intermittence
Temperature
Degree of protection
Control panel
Radio frequency
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be guaran-
teed with the use of DITEC accessories and safety devices.
2.1 Standard installation (fig. 1)
[1]
Gearmotor (1JE)
[2]
Control panel (RO2H)
[3]
Belt connection bracket
[4]
Transmission belt
[5]
Blocking device (0KAMCJE)
3.
INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres (mm).
3.1 Installation of the automation
-
Check the installation situation: right-hand opening or left-
hand opening (fig. 2).
-
Unscrew plate [A] and insert the belt as shown in fig. 2.
Close the plate and tighten the screws.
-
Fasten the belt connection bracket [B] to the door wing
(fig. 4).
-
Fasten the automation to the wall close to the opening side
of the door wing and fasten the belt to the bracket.
Note: the stroke of the door wing must be limited by suit-
able stops.
Attention: check that there is at least 20 mm between the
gearmotor and the belt connection bracket with the door
wing completely open or closed.
-
Manually tension the belt. Make any possible adjustments
on the door, the belt connection bracket or the wall fixing
screws.
OLLYE - IP1919
OLLYE
230 V~ / 50-60 Hz
0,2 A
19 V= / 1,8 A
50 N
0,1 m/s
80 Kg
3,5 m
2 = LIGHT
S2 = 7 min, S3 = 15%
-20 °C / +55 °C
IP20
RO2H
433,92 MHz
4.

ELECTRICAL CONNECTIONS

The electrical connections and activation are illustrated in the
control panel installation manual.
4.1 Radio programming
Follow the instructions in the related manual to program the
radio transmitter.
4.2 Single and centralised multilevel commands
The shutters of the house can be opened and closed with a
single command, or by means of centralised multilevel com-
mands (room commands, floor or zone commands and general
commands), by making the connections indicated in the control
panel installation manual.
5.
MAINTENANCE SCHEDULE (every 6 months)
Turn off the power.
-
Check that the fixing screws are holding (automation,
arms).
-
Check all electrical connections.
Turn on the power.
-
Check that the automation is working correctly and that
the shutters are moving correctly.
ATTENTION: For spare parts, see the spares price list.