PILOT LIGHTING PROCEDURE – VMG AND AGM MODELS
1. Turn the main gas shut-off valve and all burner control knobs to the OFF position. Wait 5 minutes to
allow any gas that may have accumulated in the burner compartment to escape.
2. Turn the main gas shut-off valve ON.
3. While viewing through the pilot sight hole, you will have to reach under the front of the unit and through
the pilot cutout to ignite the pilots with an outside ignition source (such as a lit taper, etc.). It may be
necessary to adjust the pilot valve to increase gas to the pilot.
4. Repeat steps until all pilots are lit
5. To light main burners, turn individual burner control knobs to the full ON position.
6. If after completing steps 1-5 main burners do not light, turn off the main gas shut-off valve and
contact an authorized service contractor.
pilot burner
pilot cutout
Fig. 13
12"
CUTAWAY VIEW
14
-
-
pilot sight
hole
burner control
knob