Malfunction
Material leaking at
material needle seal
Material not flowing
Atomization too coarse Inlet pressure too low.
No material or insuffi-
cient material at nozzle
14. After Sale Service
Please contact your SATA dealer for accessories, spare parts and techni-
cal support.
15. Accessories
Art. No. Description
16071
Rigid door wand (steel) 43.3" long, Ø 0.3", with radial
nozzle 360° radial fan, spraying forward
Operating Instructions for SATA HRS
Cause
Material needle seal is
defective.
Pressure not supplied
to pressure cup.
Material viscosity is
too high.
Wand diameter is too
small.
Wand tip is soiled.
Corrective action
Replace material
needle seal [3-6]
(see 11.3).
Connect to com-
pressed air circuit.
Remove check valve
[1-18], clean and, if
necessary, replace
(see 12.3).
Remove inlet valve
[3-9], clean and, if
necessary, replace
(see 11.4 and 12.4).
Remove quick connect
coupling [2-4], clean
and, if necessary, re-
place (see 11.1).
Increase inlet pres-
sure.
Use larger diameter
wand.
Clean wand tip (see
12.2).
Quan-
tity
1 ea.
US
37