Operating Instructions for SATA HRS
US
Description
Weight of HRS-E variant with material
flow control
9. Initial Operation
The pressure spray gun is delivered completely assembled and ready for
operation.
After unpacking check whether:
■ Damage to pressure spray gun
■ The scope of delivery is complete (see 5)
Explosion risk!
An explosion may result if unsuitable air hoses are used.
→ Use only undamaged, solvent-resistant, anti-static air hoses in good
working condition that have a continuous compression strength of at
least 290 psi,, and an inside diameter of at least 0.4" as well as a
leakage resistance of < 1MOhm, such as the SATA air hose (Art. No.
53090).
Information!
Use a compressed air connection with a 1/4" male thread or suitable
SATA quick connect nipple.
Use uncontaminated compressed air by using an SATA filter 484 (Art.
No. 92320), for example.
■ Check all screws for tightness.
■ Connect compressed air line to flushing connection [1-12].
10. Normal Operation
Check with the manufacturer prior to using the pressure spray gun to
ensure that the cleaning and preservative media can be used with the
pressure spray gun.
30
Danger!
Variation with aluminum
pressure cup