Preface; Introduction; Identification Of The Product; General Description - PLYMOVENT ControlPro Manuel D'installation

Masquer les pouces Voir aussi pour ControlPro:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

pREFacE

using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
pictograms and symbols
The following pictograms and symbols are used in this manual:
tip
Suggestions and recommendations to simplify
carrying out tasks and actions.
attENtioN
A remark with additional information for the user. A
remark brings possible problems to the user's
attention.
cautioN
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WaRNiNg
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
cautioN
Denotes risk of electric shock.
text indicators
Listings indicated by "-" (hyphen) concern enumerations.
Listings indicated by "•" (bullet point) describe steps to
perform.
product indications / abbreviations
Product type:
Equals to:
- ControlPro/Panel
Panel
- ControlPro/HMI
HMI
- Control/SlaveBoard
SlaveBoard
- MDB PRO
MDB
- SCS PRO
SCS
- EDS PRO
EDS
- MultiDust Bank
MDB
1

iNtRoDuctioN

1.1

Identification of the product

The identification plates contain, among other things, the
following data:
- product name
- serial number
- supply voltage and frequency
- power consumption
1.2

General description

ControlPro of Plymovent is an intelligent control panel with
separate HMI, that is supplied including the required
connection cables. This system controls the fan and the
compressed air valves of the connected filter system MDB,
SCS or EDS.
1.
Human Machine Interface
0000112606/200917/0 ControlPro
1
1.2.1
ControlPro + MDB
Fig. 1.1
A
Filter system MDB
2
B
SlaveBoard
3
C
Panel [control panel]
D HMI
E
Fan control equipment (refer to paragraph 1.3)
F
Extraction fan (refer to paragraph 1.3)
A
Fig. 1.1
ControlPro + MDB
1.2.2
ControlPro + SCS / EDS
Fig. 1.2
A
Filter system SCS / EDS
B
Panel [control panel]
C
HMI
D Fan control equipment (refer to paragraph 1.3)
E
Extraction fan (refer to paragraph 1.3)
A
B
Fig. 1.2
ControlPro + SCS / EDS
1.3
product combinations
1.3.1
Required products
To operate the system, selection of the following products is
necessary:
Extraction fan
- Plymovent SIF
(Outdoor)
Mounting frame
- Plymovent FRAME SIF
2.
Shown: rear of the filter system
3.
Integrated on the rear of each filter module
B C
D
E
F
C
D
E
specific type and motor power
depends on the configuration
specific type depends on the
selected extraction fan and
configuration