the side of the calling module. In the first case, use
the three module embedding box Ref. 1155/63.
The module is programmed by default with a jumper
between the earth and the "SP" signal to simulate the
door closed contact. Remove the jumper and connect
the sensor between GND and SP when the open
door contact is required. Connect the electrical lock
positive to terminal SE1 and the negative to terminal
SE2 when polarised electrical locks are used.
PROGRAMMING
The module can be programmed in three ways
when the system is powered:
1
Via external keyboard 1032/65 (recommended
method).
2 Via local numeric keypad without opening the
frame. The programming password is required
for this operation.
3
Via PC connection.
Repetitive beeps and a message on the display in
programming will signal that other modules with the
same ID are present. Change the station number
(ID) in this case.
PROGRAMMING VIA KEYBOARD 1032/65
Programming mode is entered automatically by
connecting the external keyboard to the call module.
Programming mode is quitted by disconnecting the
external keyboard in any menu. All previously entered
data will remain valid. See "Programming parameters".
Functione
Select menu
OK (enter)
Escape (one menu up)
Whitespace
Backspace (for correction)
Select special characters
Delete booking of code
to be associated
20
PROGRAMMING VIA LOCAL KEYPAD
Programming mode can be accessed in two ways.
• The configuration access password is known
(the default password is "9999"): enter "00" followed
by the 4-digit password and press A. The following
message will appear if the password is wrong:
Password entry will be jammed for a time which
increases with the number of failed attempts after
the third attempt.
• The password is not known: open the K-STEEL
frame and press the red button on the back. The
red programming button on the back of the unit
can be pressed in any programming menu. The
data entered to this time will be valid. Press for
three seconds to go back to the previous menu.
Press
programming. Normal operation is automatically
restored if no buttons are pressed for over three
minutes.
PROGRAMMING PARAMETERS
Refer to the local keypad programming method for
programming menu operative descriptions.
The following table shows the operative differences
for programming via keyboard 1032/65.
Programming via
local keypad
Buttons
and
Button
Button
pressed for 3s
Separate characters
Separate characters
Separate characters
Button
INCORRECT
PASSWORD
for three seconds in the main menu to quit
Programming via
external keyboard
Buttons ← and →
Button ↵
Button
Button SP
Button BS
Button /
Button BS
DS1072-018A