7 Adjustable call module speaker volume.
8 Adjustable call module microphone volume.
9
Programming alphanumeric keyboard (1032/65)
connector (CNP).
10 Programming button (for use only when
password is not known).
11 Adjustable LCD contrast.
12 Extractable connection terminal board (MP1).
13 PC wire connector (CNS).
DESCRIPTION OF TERMINALS AND
CONNECTORS
MP1 terminal board
~0
Power 12Vac
~12 Power 12Vac
+T
Back-up power positive
GND Back-up power negative
SE1
Electrical lock connection
SE2
Electrical lock connection
MP2 terminal board
L1
Bus line 1st wire
L2
Bus line 2nd wire
GND Reference electrical earth
PA
Hall door opener button input
SP
Open door sensor contact input
MV1 terminal board
SN
Video power unit on signal for video systems
R
Video switching enable signal for video systems
R1
Video power earth
MS1 terminal board
H
Door opener code time band contact input
P
Mail key input
GND Reference electrical earth
+EP Auxiliary device power
DT
Not used
CNA Alphabetic keyboard connector 1038/73
CNP Programming keyboard connector 1032/65
CNS PC serial line connector
DS1072-018A
TECHNICAL SPECIFICATIONS
Power:
Stand-by consumption:
Maximum consumption:
R signal:
Lock hold current:
Working temperature range: -10 +50°C
Humidity:
(*) with alphabetic keyboard connector 1038/73.
INSTALLATION
IMPORTANT:
Observe the instructions contained in the
"Integrated System Technical Manual - Bibus"
for wiring and maximum distances.
The calling module must be fitted in K-Steel
embedding boxes, e.g. Ref. 1152/62 (not provided).
For fitting, loosen the two tap screws and remove
the crossbar from the embedding box frame. Then
fasten the calling module to the frame by means of
seven M3 screws (provided) as shown in the figure.
n° 7 M3
Tamperproof screws are provided with the K-Steel
frame for greater security.
The additional alphabetical keypad Ref. 1038/73
can only be fitted under, or, if this is not possible, by
12Vac nominal
300mAac max.
600mAac max. (*)
Imax = 80mA
190mA max.
90% RH @ 30°C
19