5-11. Connection For Hobart Welding Power Sources With 5-Socket And 115 Volt AC
Receptacles
E
D
C
B
A
4
2
Tools Needed:
1/4 in.
5-12. Connection For Lincoln Welding Power Sources With 14-Socket Receptacle
E
D
C
B
A
1
Tools Needed:
1/4 in.
.
Make ground lead connections
according to Section 5-7 before
following this procedure.
1
3
.
Make ground lead connections
according to Section 5-7 before
following this procedure.
3
2
1
Terminal Block 1T
2
3-Conductor Cord
3
2-Conductor Cord
4
Green Lead (Connected To
Ground In Section 5-7)
Connect
terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: Dry Contact Closure w/Respect
To Terminal E Lead
E
E: 115 VAC/Contact Closure Lead
D
A
.
C
B
For welding power sources
requiring dry contact closure,
move lead 38 at terminal block
to terminal D.
Secure strain relief clamp around
cords.
Reinstall and secure wrapper to
unit.
Connect remaining cord ends to
welding power source.
1
Terminal Block 1T
2
Interconnecting Power Cord
3
Green Lead (Connected To
Ground In Section 5-7)
Connect
terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: Dry Contact Closure w/Respect
To Terminal E Lead
E: 115 VAC/Contact Closure Lead
.
For welding power sources
H
requiring dry contact closure,
G
I
F
N
J
move lead 38 at terminal block
M
K
A
E
L
to terminal D.
D
B
C
Secure strain relief clamp around
cord.
Reinstall and secure wrapper to
unit.
Connect remaining end of cord to
welding power source.
.
Move wire 38 from T1-C to ter-
minal 1T-D.
remaining
leads
to
Ref. 802 310 / Ref. 193 749
remaining
leads
to
Ref. 802 310 / Ref. 193 749
OM-193 471 Page 21