ULTRAFLEX
3.7 Throttle connection
B110-ETC lever is equipped with a sensor that can communicate directly with the system on the boat.
The sensor used has a redundant analogue output signal, which can also be single if required. To
check the values of the output signal, refer to the enclosed leaflet.
For customisation of the sensor output voltage curve, please contact our Technical Assistance Service.
6-POLE CABLE AT SENSOR
SENSOR SIDE CONNECTIONS
CAUTION
Incorrect connection of the sensor can damage it. In case of doubts, always contact the Technical
Assistance Service.
CAUTION
Before powering the system, check that the wiring has been carried out correctly; incorrect wiring can
damage the system. In case of doubts, always contact the Technical Assistance Service.
page 18
of 67 -
SINGLE LEVER CONTROL B110-ETC
OUTPUT
Cable wiring diagram
GND - BLUE
Signal - PURPLE
V+ - BROWN
GND - BLACK
Signal - WHITE
V+ - RED
Installation and maintenace manual
MALE CONNECTOR AMP 282108-01 with
6 Pins AMP 282404/1
6 Cable grommets AMP 281934/4
CONNECTOR SIDE CONNECTIONS