LP Tank Requirements
A dented or rusty LP tank may be hazardous and should be checked by your LP supplier. Never use a cylinder with a damaged
valve. The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the
U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes
for Transportation of Dangerous Goods; and Commission, as applicable. Overfilling prevention device (OPD) shall be provided
on cylinder & QCCI connection on the cylinder valve, ANSI/CGA-V-1. The cylinder supply system must be arranged for vapor
withdrawal. The cylinder must include a collar to protect the cylinder valve. The cylinder must be provided with a shut off
valve terminal in an LP gas supply cylinder valve outlet specified, as applicable, for connection type QCC1 in the standard for
compressed gas cylinder valve outlet and inlet connection ANSI/CGA-V-1.
Manifold pressure: 11" water column (W.C.).
LP Gas Hook-up
Make sure that the black plastic grommets on the LP cylinder valve are in place and that the hose does not come into contact
with the grease tray or the grill head.
Connecting an LP Gas Tank
Your stainless steel grill is equipped with gas supply orifices for use only with liquid propane gas. It is also equipped with a high
capacity hose/regulator assembly for connection to a standard 20 lb. (9 kg) LP cylinder [18.5 in. (469.9 mm) high, 12 in. (304.8
mm) diameter].
To connect the LP gas supply cylinder:
1. Make sure that the tank valve is in the off position (turn clockwise to stop).
2. Check the tank valve to make sure that it has proper external male threads (type 1 connection per ANSI Z21.81).
3. Make sure that all burner valves are in the off position.
4. Inspect the valve connections, port, and regulator assembly. Look for any damage or debris. Remove any debris. Inspect the
hose for damage. Never attempt to use damaged or obstructed equipment. See your local LP gas dealer for repair.
5. When connecting the regulator assembly to the valve, hand tighten the quick coupling nut clockwise until it stops. Do not
use a wrench to tighten. Use of a wrench may damage the quick coupling nut and result in a hazardous condition.
6. Open the tank valve fully (counterclockwise). Apply a soap solution with a clean brush to all gas connections. If growing
bubbles appear in the solution, the connections are not properly sealed. Check each fitting and tighten or repair as
necessary.
7. Apply a soapy solution to the tank seams. If growing bubbles appear, shut the tank off and do not use or move it. Contact
an LP gas supplier or your fire department for assistance.
NOTICE
If you have a gas connection leak you cannot repair, turn the gas off at the supply tank, disconnect the fuel line
from your grill, and call 1-800-913-8999 or your gas supplier for repair assistance.