Safety Precautions and Usage Statements
the mattress by retracting only with gravity, never pulling downwards, which
minimizes pinch points.
LIFTING/LOWERING MECHANISMS
The lift/lower feature will emit a minimal humming sound during
operation.This is normal. During operation, the lift arm wheels make contact
with the platform support of the base. This contact may result in metal on
metal or metal on plastic contact. This applies slight tension on the moving
components and resonance is reduced to a minimum level. If excessive noise
or vibration is experienced, reverse the movement action (up or down) of the
base with the remote control. This should realign the base's activating
mechanisms to the proper operational position. In normal base operation,
the wheels, which allow the bed to maintain its distance from the wall, will
make contact with the steel platform supports of the base creating a contact
noise. When entering, exiting or shifting weight on the base, this contact
noise may be audible as the wheels make contact. This is normal.
MATERIALS
Ergo adjustable bases are constructed from various materials including
woods, metals, plastics and fabrics. Tension, pressure or movement applied to
the frame, platform or shroud through general use may create an audible
sound.
MASSAGE OPERATION AND LOCATION ENVIRONMENT
The massage feature will emit a tone during operation. This is normal. As the
massage intensity level is increased, the tone will intensify. The volume of this
tone is directly related to the location environment. For example, when
demonstrated in a show room, the surrounding environmental noise will
cover some of the massage noise. However, when installed in a home setting
with wooden floors, carpeted or not, the massage volume will be more
noticeable. To minimize this resonance, place a piece of carpet, or rubber
caster cups, under each leg or caster of the base. It is possible to experience
vibration
or noise from the exterior bed frame, headboard brackets, headboards or
footboards if mounting bolts are not firmly tightened.
2
Levels 1-6 of massage intensity represent the revolutions of the motor per
minute. Level 6 provides the maximum number of RPMs. However, this does
not mean that the feeling of vibration is the strongest. Depending on the
mattress material, thickness, and positioning of the user, the feeling of
vibrations will differ. We encourage the user to find the massage intensity
setting that suits them best. It is important to understand the physics of
vibrations. Just as an engine may run rough during idle, as the RPMs increase,
the vibrations change concurrently.
TOLERANCE
All Ergo adjustable foundations, depending on make and model, are designed
and manufactured to perform and function within designated quality control
parameters. Bases are subject to meticulous and rigorous inspections
during the quality control process to ensure bases will operate within these
standards during normal operating use. Normal operating use is defined as
the following: Adjustable foundation is to be operated with a mattress and
load. Testing procedures require lifetime cycle tests with up to 120kg
distributed load. The angle (designated "α" in figure 1) between the back
section and the flat section for various configurations of the mattress support
platform shall be ± 3°, which translates to a tolerance of up to 1 ½". The
angle (designated "β" in figure 1) between the flat section and foot section for
various configurations of the mattress support platform shall be ± 3°, which
translates to a tolerance of up to ¾". Any
adjustable foundation deemed to
be within these allocated tolerances is
considered to have met the manufacturer's
quality control standards.
THAT "NEW PRODUCT" SMELL:
Some people notice a slight odor to their
new adjustable base—this can come from our material manufacturing
process. This smell is normal and usually disappears before the product
reaches you. Sometimes, however, this smell may still be noticeable. It usually
disappears after a few weeks, providing adequate ventilation of the product
and the environment.
Adjustable
Bed Tolerance
All Ergomotion adjustable foundations, depending on make and model, are designed and manufactured to perform and
function within designated quality control parameters. Bases are subject to meticulous and rigorous inspections during
the quality control process to ensure bases will operate within these standards during normal operating use.
Normal operating use is defined as the following:
-Adjustable foundation is to be operated with a mattress and load. Testing procedures require lifetime cycle
tests with up to 120kg distributed load.
The angle (designated "α" in figure 1) between the back section and the flat section for various configurations of the
mattress support platform shall be ± 3°, which translates to a tolerance of up to 1 ½".
The angle (designated "β" in figure 1) between the flat section and foot section for various configurations of the mattress
support platform shall be ± 3°, which translates to a tolerance of up to ¾".
When operating a "paired" split base setup there may be a time latency up to 1.5 seconds between each bases articulation.
Any adjustable foundation deemed to be within these allocated tolerances is considered to have met the manufacturer's
quality control standards.
(β°)
Blake Pettit
Quality Assurance Manager
Ph 805-979-3875
Fx 805-979-9399
www.ergomotion.com
Ergomotion Inc.
|
ph 1-888-550-3746
|
fx 805-979-9399
|
www.ergomotion.com
(α°)