power of the motor to be converted into uniform rotary
impacts. The impact mechanism comes into effect
during tightening and loosening.
The appliance is designed for use by adults. Young
people under 16 years of age may only use the
appliance under supervision. The manufacturer accepts
no liability for damages caused by improper
use or incorrect operation of the appliance.
Use this product only as described and for the
areas of applications specified. The appliance is
not intended for commercial use. Any other usage
or modification of the appliance is deemed to be
improper and carries a significant risk of accidents.
The manufacturer accepts no responsibility for
damage(s) attributable to misuse.
10. Installation
m IMPORTANT!
You must fully assemble the appliance before
using it for the first time!
To ensure that the Li battery pack provides long ser-
vice you should take care to recharge it promptly.
You must recharge the battery pack when you notice
that the power of the cordless equipment drops.
Use
Switching on and off
Switching on:
To start the appliance, press the ON/OFF
switch and keep it pressed in.
The LED working light lights up when the
ON/OFF switch is depressed lightly or fully.
This provides illumination of the work area in
poor lighting conditions.
Switching off:
Release the ON/OFF switch to switch off the
appliance.
Setting/preselecting the rotation speed/tighten-
ing torque
Press the ON/OFF switch lightly for a low
speed/tightening torque. Increasing the pressure
increases the speed/tightening torque.
The tightening torque depends on the selected
speed/torque preselection and impact duration.
NOTE
However, to tighten lug nuts, the smallest
torque setting must be selected to avoid over
tightening.
CAUTION!
The tightening torque actually attained must
always be checked with a torque wrench!
22 | GB
www.scheppach.com service@scheppach.com +(49)-08223-4002-99 +(49)-08223-4002-58
All manuals and user guides at all-guides.com
NOTE
The integrated motor brake ensures rapid
stoppage.
Changing the direction of rotation
Change the direction of rotation by pressing
the rotation direction switch towards the left
or right.
Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the ap-
plicable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking
The printing of the type designation on the connec-
tion cable is mandatory.
11. Cleaning
Danger!
Always pull out the battery pack before starting any
cleaning work.
Cleaning
• Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it
with compressed air at low pressure.
• We recommend that you clean the device immedi-
ately each time you have finished using it.
„.