Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
GB
IRL

Care and maintenance

Disassemble the pump [4] and grease the diaphragm [17]
ing water
Grease the O-rings [22] and [23]
the device in regular intervals.
Faults
parts pouch [3],
Fault
No pressure builds up in
the device.
Liquid is forced up out of
the air pump.
The nozzle does not
sure is present.
there is no atomization.
not close.
Liquid emerges without
the lever being activated.
Contact address for additional information
AUS
USA
Cause
The pump is not screwed on
O-ring [22] on the pump is
.
.
Filter [20]
-
and nozzle [18]
clogged.
Insert [19] is missing
O-ring [23] of the pressure
bolt is not greased / lubrica-
te
O-ring [23]
NZ
.
Remedy
Replace the O-ring.
Replace the diaphragm.
Clean or replace the valve disc.
or /
is
Position the insert in the nozzle.
Grease the O-ring of the pressu-
re bolt.
Replace the pressure bolt or
O-ring.