5. Electrical wiring.
Description of terminals.
Terminal block M1
Terminal number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Terminal block M2
15
16
17
18
19
20
21
22
23
24
25
Wiring for power supply line, flashing lamp and electric motors.
The actuators are already fitted with an electrical cable connected to the motor. This cable is 0.8 m long and must be connected in a specific junction
box mounted on the pillar, if the control unit cannot be reached directly.
Function of the actuator cables
Colour
Yellow-Green
Grey
Black (EAM8.L) - Brown (EAM8.R)
Brown (EAM8.L) - Black (EAM8.R)
Board marking
Description
SEQ
Push button (N.O.) for opening and closing (sequential or start)
STOP
Push button (N.C.) for stop
PED
Push button (N.O.) for pedestrian opening
SCL
Input (N.C.) for closing safety devices (reopening)
SOP
Input (N.C.) for opening and closing safety devices (momentary stop)
COM
Common inputs and indicator light (negative)
+AS
Positive for 24 VDC accessories power supply
-AS
Negative for 24 VDC accessories power supply
+WL
Positive for indicator light 24V 2W max
COM
Common inputs and indicator light (negative)
+LOCK
12 VDC positive (possible 12 VAC 15W max electrical lock)
-LOCK
12 VDC negative (possible 12 VAC 15W max electrical lock)
P.IN
Programmable input (N.C.)
+P.OUT
24 VDC positive programmable output
Input for earth connection
L
Input for 230/120 V 50Hz line (PHASE)
N
Input for 230/120 V 50Hz line (NEUTRAL)
FL
Flashing lamp 230/120 V 50Hz 25W max (NEUTRAL)
FL
Flashing lamp 230/120 V 50Hz 25W max (PHASE)
M1COM
Common motor 1 winding input
M1CL
Motor 1 closing direction input
M1OP
Motor 1 opening direction input
M2COM
Common motor 2 winding input
M2CL
Motor 2 closing direction input
M2OP
Motor 2 opening direction input
EARTH
230/120 VAC
Description
Earth connection
Common
Motion 2 (Door closing movement, rod extension)
Motion 1 (Door opening movement, rod withdrawal)
EN
Terminal on board
Motor 1
Motor 2
15 PE
15 PE
20 M1COM
23 M2COM
21 M1CL
24 M2CL
22 M1OP
25 M2OP
23